INTRODUCTION

The frequency of traumatic fractures has increased considerably over recent years, mainly as a result of vehicle accidents and diseases affecting bone metabolism(1). Thus, different orthopedic treatments for stimulating and accelerating bone regeneration have been widely investigated. Among these, the use of fundamental bone grafts in clinical cases of comminuted or explosive fractures in which there may be a need to use a graft because of the considerable loss of bone mass, according to the trauma energy or severity of the bone disease, has been highlighted.

As an alternative to repairing these fractures, with or without a possible association with autogenous bone grafts or other factors that induce osteogenesis, the use of biomaterials has also been highlighted because of their osteogenic properties and biocompatibility, along with the ease of construction, given the advances in tissue engineering that have be made. Thus, hydroxyapatite and collagen are among the various materials that have been receiving special attention in many studies that have sought synthetic implants that might be ideal for osteoconduction, biocompatibility and biomechanical resistance during the repair process on bone defects or in regeneration from fractures(2-10).

Hydroxyapatite has good bone conductibility, which influences its reabsorption speed and is regulated mainly by the porosity of the material(11). Direct stable contact between this biomaterial and the bone stimulates osteogenesis and therefore osseointegration of the biomaterial( 12). Nandi et al(13) carried out a study to evaluate the efficiency of porous hydroxyapatite in bone defects that had been created in the diaphysis of the radius in goats, and observed good bone formation and revascularization in the area grafted with hydroxyapatite, thereby confirming the natural biological osteoconductive property of this material.

The indications for the use of hydroxyapatite are directed towards correction of cranial maxillofacial defects, traumatic events and congenital deformities, and may also be used in plastic surgery(14,15). Other substances that deserve attention are natural polymers, which have been used in many applications(16).

Natural polymers like collagen not only are biocompatible but also participate in controlling the structure of the tissue and in regulating the cell phenotype, thus simulating the extracellular matrix. Collagen is the most abundant fibrous protein in the human organism, representing 25 to 30% of the total protein mass in mammals. Since collagen is the main organic compound in bone tissue, it has been widely used for manufacturing biomaterials(17).

The biocompatibility and stability of collagen, which are due to its biological characteristics of biodegradability and bioabsorbability, its antigenic debility and its capacity for easy manipulation into different forms, make it a fundamental resource for medical application( 18). Takaoka et al(19) used collagen from demineralized bone together with hydroxyapatite for treating congenital and acquired orthopedic defects. From their results, they noted that collagen from demineralized bone grafted in combination with hydroxyapatite was an excellent osteoinductive material in association with bone morphogenetic protein (BMP).

The aim of the present study was to evaluate the osteoconductive capacity of hydroxyapatite and collagen in the bone repair process in defects caused by removal of part of the middle third of the fibula in rats.

METHODS

Animals

Fifteen adult albino Wistar rats (Rattus norvegicus) were used, which came from the vivarium of Jundiaí School of Medicine. The animals were divided as follows:

Group TS: animals that received an empty silicone tube in the defect that was created in the fibula;

Group TH: animals that received a silicone tube filled with hydroxyapatite in the defect that was created in the fibula;
and
Group TC: animals that received a silicone tube filled with collagen in the defect that was created in the fibula.

Surgical procedure

Firstly, the animals were weighed and anesthetized with a solution of ketamine (Francotar) and xylazine hydrochloride (Virbaxyl 2%), in proportions of 1:1 and at a dose of 0.10 ml/100 grams of body weight, intramuscularly. The animals were placed in dorsal decubitus and a longitudinal incision was made in the skin of the anterolateral region of the left leg. The musculature was moved aside in order to expose the fibula. With the aid of surgical materials, a defect was produced by removing approximately 2 mm from the middle third of the fibula. Silicone tubes were placed in this site.

Radiological evaluation

Eight weeks after the implantation, the animals were sacrificed and the leg bones were subjected to radiography using the FUNK-X10 apparatus with a focal point of 0.8 x 0.8 mm and Kodak radiographic film measuring 4.4 x 3.3 cm.

Histological evaluation

The samples were subjected to the histological techniques of fixation, decalcification and slide production, with semi-serial longitudinal sections in the area of the bone defect filled with silicone tubes.

Morphometric study

The neoformed bone was quantified by means of stereology, in accordance with the Delesse principle (Mandarim de Lacerda, 1999). The following formula was used:
VV = PP/PT (%), where:
VV = volume density or relative volume; }
PP = quantity of points (line intersections) over the neoformed bone; and
PT = total number of points in the system. By means of a quadrilateral grid of 100 points coupled to the eyepiece of a Carl Zeiss optical microscope, the density of the neoformed bone volume in the area of the implanted silicone tubes was calculated, starting from the extremity of the fibular fragment. This analysis was performed with the objective lens of the optical microscope standardized as a magnification of 4x.

Statistical evaluation

The technique used for analyzing the morphometric data was evaluation of three independent samples and parametric means, using the Watson-Williams method.-

RESULTS

Radiological evaluation In the animals of the groups TS, TH and TC, it was seen that there was good interaction between the silicone tube and the surrounding tissue, given that there was a clear radiopaque image of the outline of the tube and no radiological sign of pathological abnormalities (Figures 1, 2 and 3).


Figures 1, 2 and 3 - Groups TS, TH and TC Note the radiopacity of the implanted silicone tube (S). Key: T = tibia; F = fibula.

Histological evaluation

In the animals of the group TS, it was noted that the interior of the silicone tube was partially filled with connective tissue, without indications of bone neoformation (Figure 4). In addition, there was a proliferation of bone tissue from the fibular fragment towards the end of the implanted tube (Figure 5). In the animals in the groups TH and TC, it was observed that as well as connective tissue, areas of bone neoformation were present inside the silicone tube, together with young bone growing from the end of the fibular fragment (Figures 6 and 7). Morphometric and statistical evaluation From quantification of the percentage of neoformed bone in the area of the implant, it was seen that the values were greater for the groups TH (10.2%) and TC (13.4%) than for the group TS (2.6%). Statistically, the values were different between the groups (p < 0.05) (Figure 8).


DISCUSSION

The clinical limitations on the use of autogenous bone grafts in fractures with bone loss have led several studies towards advances in the field of tissue engineering and biomaterials, with the aim of manufacturing synthetic materials that would be capable of promoting fast osteogenesis and incorporation with bone tissue through osteoconductive and osteoinductive stimulation, without generating rejection complications associated with their use, as an essential biocompatibility factor, in addition to providing biomechanical resistance at the implant site(20). Hydroxyapatite and collagen meet these requirements and have been receiving considerable attention within the fields of plastic surgery, orthopedics and dentistry(21).

Duarte et al(22) used synthetic hydroxyapatite in a defect in the alveolar process of the mandible of dogs and observed intense proliferation of osteoblasts and neovascularization in the presence of the implant. Camilli et al(23) implanted hydroxyapatite subperiosteally in the femur of rats and observed good bone neoformation in the area of the implant, as well as biocompatibility. Similar results were also described by Pinheiro et al(24) from implantation of hydroxyapatite in a bone defect created experimentally in the distal third of rats. Cunha et al(8) implanted collagen in defects in the femur of rats and noted that there was good closure of the area because large quantities of bone had formed. They concluded from biomechanical tests that the regenerated area presented good mechanical quality.

In addition to the importance that biomaterial implants should present biocompatibility and osteoconductive capacity for the bone regeneration process, the mechanical quality and type of embryological ossification of the bone are also fundamental. Camilli et al(23) observed that the femur, which is an endochondral bone, responded better to hydroxyapatite implantation than did the skull cap, which originates from membranous ossification. Raab et al(25) stated that the mechanical function of the bone influenced the resistance and formation of the bone tissue. Thus, it can be seen in the literature that most studies on biomaterials have used the femur and tibia of rats because of their good biomechanical capacity and endochondral origin, which is important for the osteogenic function of the bone(8-29).

Regarding the fibula of rats, it can be seen that it presents morphological peculiarities, since the axis of the distal diaphysis of the tibia fuses postnatally with the fibula. This process starts around the seventh day, with the formation of secondary cartilage that subsequently is replaced with endochondral ossification. Thus, the fibula presents low biomechanical quality and importance(30). It is defined that the fibula presents a reciprocal role in regulating the growth of the tibia in rats. The low biomechanical influence of the fibula, even with the low action of gravity to which it is subjected, may interfere with the consolidation of fractures through its insufficient angiogenic and osteogenic function(31).

Through the anatomical factors of the fibula mentioned earlier, we could see from our investigation that the amount of bone that formed inside the tubes with biomaterials that had been implanted in the bone defects of the fibula of the rats was a small quantity, compared with the results described in the literature using the femur and tibia. Moreover, there was no bone neoformation inside the empty tubes that were implanted. This may have occurred in view of the secondary biomechanical function of the fibula resulting from its fusion with the tibia and consequent low angiogenic and osteogenic function. These morphological characteristics of the fibula suggest that in the present study, the time for which the implant was left in place up to the time of sacrificing the animals was insufficient for the complete process of osteoconduction among the biomaterials to be achieved.

Despite the low amounts of bone neoformation in the area of the implant, we could see from the radiological data that there was no rejection of the type of biomaterial used. This suggests that the materials were biocompatible, as also described by other researchers who used the same implants(32-35).

CONCLUSION

The biomaterials used had osteoconductive capacity, even though the amount of bone neoformation in our study was low. However, other factors such as the embryology, ossification type, morphology and biomechanics of the bone that is studied are fundamental in the osteogenesis process. Thus, there is a need to draw up a better standardized and more scientifically based experimentation protocol in the cases of bones like the fibula of rats for which the biological qualities and mechanical parameters are not yet well defined, since these are factors that interfere directly in the expected results regarding the bone regeneration process.

ACKNOWLEDGEMENTS

We thank the National Council for Scientific and Technological Development (CNPq) for financial support consisting of the scientific initiation bursary granted for carrying out this work.



REFERENCES

1. Letournel E. Acetabulum fractures: classification and management. Clin Orthop Relat Res. 1980;(151):81-106.
2. Alonso JE, Volgas DA, Giordano V, Stannard JP. A review of the treatment of hip dislocations associated with acetabular fractures. Clin Orthop Relat Res. 2000;(377):32-43.
3. Matta JM, Anderson LM, Epstein HC, Hendricks P. Fractures of the acetabulum. A retrospective analysis. Clin Orthop Relat Res. 1986;(205):230-40.
4. Balbachevsky D, Pires RE, Faloppa F, Reis F. Tratamento das fraturas da pelve e acetábulo pela via de Stoppa modificada. Acta Ortop Bras. 2006;14(4):190-2.
5. Liebergall M, Mosheiff R, Low J, Goldvirt M, Matan Y, Segal D. Acetabular fractures. Clinical outcome of surgical treatment. Clin Orthop Relat Res. 1999;(366):205-16.
6. Tile M. Fractures of the acetabulum. Orthop Clin North Am. 1980;11(3):481- 506.
7. Giannoudis PV, Grotz MR, Papakostidis C, Dinopoulos H. Operative treatment of displaced fractures of the acetabulum. A meta-analysis. J Bone Joint Surg Br. 2005;87(1):2-9.
8. Matos MA, Viveiros AM, Barreto BG, Pires RF. Reprodutibilidade da classificação de Tile para fraturas do acetábulo. Acta Ortop Bras. 2006:14(5):253-55.
9. Sancineto C, Barla J, Slullitel G, Della Valle AG, Comba F, Bongiovanni S et al. Reproductibilidad de la clasificacion de Letournel para las fracturas cetabulares: estudio sobre radiografias y tomografia computadorizada tridimensional. Rev Asoc Argent Ortop Traumatol. 2004;69(1):59-63.
10. Köberle G, Miranda JB, Yamanaka E, Grava ALS, Belangero WD. Fraturas do acetábulo: estudo dos resultados clínicos do tratamento cirúrgico precoce e tardio. Rev Bras Ortop. 1993;28(6):361-6.
11. Knop T, Silva LHP, Laghi R. Fraturas acetabulares: resultados de tratamento cirúrgico. Rev Bras Ortop. 1996;31(10):825-30.
12. Aho AJ, Isberg UK, Katevuo VK. Acetabular posterior wall fracture. 38 cases followed for 5 years. Acta Orthop Scand. 1986;57(2):101-5.
13. Chiu FY, Chen CM, Lo WH. Surgical treatment of displaced acetabular fractures 72 cases followed for 10 (6-14) years. Injury. 2000;31(3):181-5.
14. Deo SD, Tavares SP, Pandey RK, El-Saied G, Willett KM, Worlock PH. Operative management of acetabular fractures in Oxford. Injury. 2001;32(7):581-6.