ABSTRACT:
Reduction and fixation of glenoid cavity fractures using arthroscopy cause little
surgical trauma, allowing the complementary diagnosis and treatment of potentially
associated injuries (either capsular, ligamentous or tendon lesions) with promising
outcomes. The authors report a case of Ideberg type III glenoid fracture with a distal
clavicle fracture which underwent percutaneous reduction and bone fixation (with Kirschner
wires) using an arthroscopic technique. We describe the procedure and the outcomes
after 18 years of follow-up. The clinical assessment included the functional University
of California at Los Angeles (UCLA) score criteria and radiographic studies. The result
was excellent/satisfactory, with the patient asymptomatic over time and without relevant
radiographic changes. Although the management of glenoid fractures by arthroscopy
remains evolving, it is a good treatment alternative to the open approach, especially
in less complex fractures.
Keywords: arthroscopy; fracture fixation; glenoid cavity; scapula; shoulder fractures.
RESUMO:
A redução e fixação das fraturas articulares da cavidade glenoidal pela técnica artroscópica
causam pouco trauma cirúrgico, possibilitando o diagnóstico complementar e tratamento
de eventuais lesões associadas (capsulares, ligamentares e/ou tendinosas), sendo demonstrados
resultados promissores até o momento. Os autores relatam um caso de fratura glenoidal
tipo III de Ideberg, associada à fratura da clavícula distal, submetida a redução
e fixação óssea percutânea (fios de K) assistida pela técnica artroscópica. Descrevem
a técnica e o resultado após 18 anos de acompanhamento, com a avaliação clínica realizada
segundo critérios funcionais do score University of California at Los Angeles (UCLA) e o estudo radiográfico. O resultado
foi considerado excelente/satisfatório, com paciente assintomático ao longo do tempo
e ausência de alterações radiográficas relevantes. Apesar do manejo de fraturas da
glenoide pela artroscopia ainda estar em evolução, apresenta-se como boa alternativa
de tratamento em relação à abordagem aberta, especialmente nas fraturas de menor complexidade.
Palavras-chave: artroscopia; cavidade glenoide; escápula; fixação de fratura; fraturas do ombro.
FIGURES
| Citation: Ramos CH, Barbosa RM, Gomes YNC, Paula ALG, Gulicz LDC. Long-term Outcomes 18 Years after the Arthroscopic Fixation of a Scapular Articular Fracture: A Case Report. 59(Suppl 2):194. doi:10.1055/s-0044-1790595 |
| Note: Work carried out at the Hospital XV, Curitiba, PR, Brazil. |
|
Conflito de Interesses Os autores declaram não haver conflito de intereses. |
| Received: July 04 2023; Accepted: September 19 2023 |
INTRODUCTION
Scapular fractures account for approximately 1% of all fractures, affecting the articular surface in 10% of cases.1 Percutaneous reduction and fixation of these fractures using arthroscopy provide articular visualization with precise reduction, diagnosis, and treatment of any associated injuries (either capsular, ligamentous, or tendon lesions), lower surgical trauma reduced blood loss, and better aesthetic results.2 Studies demonstrating good outcomes are promising, but most have short or medium-term follow-up.3,4 This paper aims to report one case of displaced glenoid fracture submitted to percutaneous reduction and fixation with arthroscopy and demonstrate long-term outcomes (18 years).
CASE REPORT
The ethics committee of our institution approved this case report under number CAAE 52798421.4.0000.0020.
A 27-year-old male, right-handed patient, working as a systems analyst, suffered trauma to the left shoulder after falling off a motorcycle in January 2005. On physical examination, he presented edema and pain in the left scapular and clavicular regions with functional loss of the same shoulder. The patient presented preserved neurological function and perfusion of the upper limb and no other systemic injuries. A simple radiograph showed a scapular fracture involving the glenoid cavity, transverse and displaced, extending to the base of the coracoid process, classified as type III by the Ideberg criteria.4 On the same side, there was a displaced distal clavicular fracture (►Fig. 1). The patient underwent surgical treatment on the second day after the trauma, with reduction and percutaneous fixation of the glenoid and clavicle fractures assisted by arthroscopy.

Surgical Technique and Outcome
We put the patient in the supine “beach chair” position under general anesthesia, interscalene block, and the image intensifier in place. After arthroscopic joint inspection to rule out associated injuries, we debrided and reduced the fracture site using a dissector-type instrument under simultaneous radioscopic control (►Fig. 2). After satisfactory reduction, we performed bone fixation with two percutaneous 1.5 mm Kirschner (K) wires inserted through the superior surface of the glenoid. Lastly, we performed the supplementary percutaneous fixation of the clavicle fracture. Postoperative radiographs confirmed good reduction and K wire positioning (►Fig. 3). We immobilized the shoulder with a simple sling for four weeks and instructed the patient to start elbow, wrist, and hand exercises immediately. Gain in joint range of motion and muscle strength began after 3 and 6 weeks, respectively. We removed the K wires after radiographic confirmation of the consolidation six weeks after the index procedure. The outcome assessment included clinical examination, radiographs, and the University of California at Los Angeles (UCLA) score criteria.5 In follow-up visits 1 and 18 years after surgery, the patient was asymptomatic, with a symmetrical shoulder range of motion (UCLA score of 35, i.e., satisfactory/excellent) and no relevant radiographic changes (►Figs. 4 and 5).




DISCUSSION
The current management of scapular fractures involving the glenoid cavity and displacements higher than 3 to 5 mm recommends surgical reduction and osteosynthesis.4 Traditional surgical approaches use arthrotomy, which allows good visualization, reduction, and fixation of the fracture for early mobilization. Although effective, they usually involve extensive accesses, with significant surgical morbidity.1,2,4 The arthroscopic alternative introduced by Carro et al.6 in 1999 to treat glenoid rim fractures is an efficient option and causes less surgical trauma. Other authors have demonstrated the technique for more complex fractures, including recommendations and tips.2,4 Most publications refer to the fixation of Ideberg type III fractures, similar to our case, demonstrating satisfactory outcomes, no complications, and the advantages previously mentioned. Disadvantages include the need for local hospital structure, learning curve, and surgeon skills. Regarding the technique, most authors recommend the beach chair position due to the eventual need for conversion to open surgery.2,3,7 In 2016, Park8 reported using cannulated screws as an easier alternative, considering that the upper fragment is often single (type III fractures). Their insertion in an anterograde manner through the superior Neviaser portal offers a low risk of nerve and vessel injury.9 Guides for knee surgery can facilitate wire insertion.3 Bonczek et al.7 suggested another technical detail, i.e., using the coracoid process as a joystick for indirect reduction. Associated injuries may require fixation, such as the distal clavicle presented by our patient.10 The literature is scarce, with limited experience and short- to medium-term outcomes. Yang et al.3 reported the largest experience, with 18 cases and a mean follow-up of 2 to 5 years. Although this report refers to a single case, we demonstrated the longest follow-up time according to the literature, and our patient is asymptomatic and has no radiographic signs of glenohumeral osteoarthritis for this fracture profile. While the arthroscopic management of glenoid fractures is still evolving and requires studies with longer case series and follow-up time, it is a good treatment alternative to the open approach, especially in less complex fractures.




