ABSTRACT:
OBJECTIVE The management of bone loss represents a challenge in revisions of total knee arthroplasty
(rTKA) and in complex primary total knee arthroplasties (TKAs). The purpose of the
present study was to evaluate the midterm outcomes (5-year minimum follow-up) of knee
reconstructions with tantalum trabecular metal (TM) cones on bone defects Anderson
Orthopaedics Research Institute (AORI) 2 and 3.Materials and MethodsA retrospective analysis of the medical records of patients operated on between July
2008 and November 2014 was performed, collecting the following data: age, gender,
laterality, body mass index, etiology of arthrosis, comorbidities, AORI classification
of bone defects, causes for revision, readmissions, reoperations, perioperative and
postoperative complications, radiographic signs of osteointegration, and maintenance
of the TM support.
RESULTS A total of 11 patients with a mean follow-up of 7.28 years (standard deviation [SD]
= 1.88; range = 5.12–10 years) was evaluated, with 1 patient operated upon for a primary
arthroplasty, 6 for revision arthroplasties, and 4 for a second revision arthroplasty
(re-revision).There were complications with the surgical wound, injury to the extensor mechanism
and loosening of the femoral component in three of the patients that led to the necessity
of four procedures due to complications with the surgical wound, injury to the extensor
mechanism and loosening of the femoral component. Radiological signs of osteointegration
of the trabecular cones were observed in all patients. We did not observe migration
of the TM cones or the prosthetic components in the sample.
CONCLUSION The tantalum metaphyseal cones were able to provide efficient structural support to
prosthetic implants with radiographic signs of osteointegration in the medium term.
Keywords: arthroplasty, replacement, knee; osteointegration; knee prosthesis; biocompatible materials.
RESUMO:
OBJETIVO O manejo da perda óssea representa um grande desafio em cirurgias de revisão de artroplastia
do joelho (rATJ) e em artroplastias totais do joelho (ATJ) primárias complexas. O
objetivo do presente estudo foi avaliar os resultados em médio prazo (seguimento mínimo
de 5 anos) das reconstruções de joelho nas quais cones de metal trabecular (MT) de
tântalo foram utilizados para tratamento de defeitos ósseos tipos 2 e 3, de acordo
com a classificação proposta pela Anderson Orthopaedic Research Institute (AORI).
MÉTODOS Feita análise retrospectiva dos prontuários dos pacientes operados entre julho de
2008 e novembro de 2014, coletando-se os seguintes dados: idade, gênero, lateralidade,
índice de massa corporal, etiologia da artrose, comorbidade, classificação AORI da
falha óssea, causa da revisão da artroplastia total do joelho, reinternações, reoperações,
complicações peri- e pós-operatórias, ocorrência de osteointegração radiográfica e
manutenção da função de suporte do MT.
RESULTADOS Foram avaliados 11 pacientes com tempo médio de seguimento de 7,28 anos (desvio padrão
[DP] = 1,88; variação = 5,12–10 anos), sendo que 1 paciente foi submetido a artroplastia
primária, 6 a artroplastia de revisão e 4 a segunda revisão de artroplastia (re-revisão).
Três pacientes necessitaram de quatro reoperações devido a complicações com a ferida
operatória, a lesão do mecanismo extensor e a soltura do componente femoral. Sinais
de osteointegração dos cones trabeculados foram observados em todos os pacientes.
Não observamos migração do cone de MT ou dos componentes protéticos.
CONCLUSÃO Os cones metafisários de tântalo foram capazes de prover suporte estrutural eficiente
aos implantes protéticos com sinais radiográficos de osteointegração em médio prazo.
Palavras-chave: artroplastia do joelho; osteointegração; prótese do joelho; materiais biocompatíveis.
FIGURES
| Citation: Minamoto STN, Silva LFT, Faria JLR, Cobra HAAB, Palma IM, Mozella AP. Midterm Radiographic Results and Reoperations of Tantalum Trabecular Metal Cones in Knee Arthroplasties. 57(05):734. doi:10.1055/s-0041-1739465 |
| Financial Support There was no financial support from public, commercial, or non-profit sources. |
|
Conflict of interests The authors have no conflict of interests to declare. |
|
Study developed at the National Institute of Traumatology and Orthopedics, Rio de Janeiro, Brazil. |
| Received: April 01 2020; Accepted: July 08 2021 |
INTRODUCTION
The management of bone loss represents a huge challenge in revisions (rTKA) and complex primary total knee arthroplasties (TKAs). Bone deficiency usually presents a multifactorial etiology, such as the evolution of the joint degenerative process, the design of the old prosthesis, the mechanism of failure may be related to technical errors during the primary surgery or difficulties in removing fixed implants.1,2
Several classifications of bone defects have been proposed and, currently, the most used is the one developed by the Anderson Orthopaedics Research Institute (AORI). In this system, the defect is classified after removal of the implant. Type 1 defects present intact metaphyseal bone with minor flaws that do not compromise support and fixation of the revision implant; type 2 defects compromise the metaphyseal bone of one (2A) or both femoral condyle or tibial condyles (2B), and type 3 defects present cortical and cancellous bone deficit in the metaphysis, occasionally associated with collateral ligament detachment.3
The proper management of these bony defects depends, among other factors, on its size, location, configuration, and cortical involvement. Therefore, there are several options for treating these bone deficiencies, such as the utilization of methylmethacrylate augmented with screws, modular metal wedges, autologous bone and allograft and, more recently, trabecular metal (TM) in the form of cones or metaphyseal sleeves. 2-5
Despite the existence of these options, the ideal one for the treatment of AORI 2 or 3 defects remains controversial.4 Structural allografts, although widely used, presents significant disadvantages, such as bone resorption, graft fracture, nonunion to the host bone, possibility of diseases transmission, and limited availability.5 Another important limitation of this method refers to the durability of its support capability in the medium and long-term.6
Thus, tantalum TM cones represent a modern option for treating these major bone failures,6-8 given their greater potential for biological fixation and, thus, for the promotion of structural support and immediate mechanical stability. Several studies have demonstrated the effectiveness of tantalum cones in providing stable fixation, reliable support, and high osteointegration index, with good short-term clinical results.6-11 However, long-term follow-up is needed in order to evaluate the durability of these reconstructions.
The aim of the present study was to evaluate the medium-term results, with a minimum 5-year follow-up, of complex primary and revision TKAs in which tantalum metaphyseal cones were used for the treatment of large tibial and/or femoral bone defects.
MATERIALS AND METHODS
After approval by the Research Ethics Committee (CAAE no. 06896019.8.0000.5273), a retrospective analysis of the medical records of all patients who had been operated upon for a primary or revision total knee arthroplasty (TKA) was performed in the period between July 2008 and November 2014. There was no age limit or restriction regarding the gender of the participants.
The following data were collected from all patients: age, gender, laterality, body mass index (BMI), etiology of the arthritic process, comorbidities, AORI classification of the bone failure, cause of TKA revision, readmissions, reoperations, perioperative and, postoperative complications, and outcomes.
Bone defects were categorized according to the AORI classification by the three senior authors and, in case of disagreement, it was opted to to consider that which had been reached a simple majority. The authors also performed the analysis of the X-ray sequences to determine the occurrence of osteointegration, and the maintenance of the support function of tantalum cones. The criterion for defining the occurrence of osteointegration was the presence of a bony reaction at the trabecular metal-host bone interface, configured by the presence of sclerosis associated with the absence of radiolucency lines. The maintenance of the support function was evaluated through eventual migration of the implants or by the presence of a progressive radiolucency line.
Descriptive analyses for quantitative data were performed, and the means were presented, accompanied by the respective standard deviations ( ± SD), medians, minimum and maximum values and first and third interquartile interval (IQ). Categorical variables were expressed through their frequencies and percentages. All analyses were performed with IBM SPSS Statistics for Windows version 21 (IBM Corp., Armonk, NY, USA) with a significance level of α = 0.05. The implant survival analysis was not performed due to the low number of participants in the research.
RESULTS
From November 2008 to November 2014, TM was used to treat large bone defects in 19 complex primary arthroplasty or knee revision surgeries. One patient died due to clinical complications 40 days after the procedure. Another patient with a periprosthetic fracture and deep infection after open reduction and internal fixation (ORIF), had to have an above-the-knee amputation (AKA) amputation 2 years after the index surgery. Six patients were excluded due to loss to follow-up. Therefore, 11 patients with a minimum 5-year follow-up for the implantation of the metaphyseal TM cones had their data analyzed (►Figures 1 and 2).

The mean follow-up was 7.28 years (SD = 1.88; range = 5.12–10 years). The mean age of the patients at the time of the procedure procedure was 67.54 years (SD = 10.74 years; range = 45–86 years). Eight patients were female (72.72%) and 3 were males (27.27%). The mean BMI was 29.78kg/m2 (SD = 6.36; range = 22.76–43.41 kg/m2). Mean length of stay (LOS) was 6 days (IQ = 4.50–7.50). The distribution of Charlson comorbidity score ranged from 0 to 5, and most patients had Charlson Index 2.
Four procedures were performed on the right knee and seven in the left knee. One patient with Charcot-like arthropathy underwent primary arthroplasty (9.09%) with revision components (rotating hinged knee). Six other patients underwent revision arthroplasty (54.55%), and second revision (re-revision) was performed in 4 cases (36.26%). ►Figure 3 shows the distribution between septic and aseptic failures of the cases of revision (rTKA) and re-revision. ►Table 1 demonstrates the causes of aseptic failures.
| Revision | Re-revision | |
|---|---|---|
| Pain | 1 | 0 |
| Instability | 1 | 1 |
| Aseptic loosening | 2 | 1 |
| 4 | 2 |

Regarding surgical pathways, surgery was performed by conventional approach in 9 surgeries (81.81%) and by extended approach in 2 surgeries. The Coonse-Adams approach was used in an aseptic re-revision case, while osteotomy of the anterior tibia tuberosity (TTO) was the choice in aseptic revision surgery.
In eight patients, highly constricted implants (Rotating Hinge Knee – Zimmer Biomet, Warsaw, IN, EUA) were used, and semiconstricted implants (Legacy Constrained Condylar Knee – Zimmer Biomet, Warsaw, IN, EUA or Total Condylar 3–DePuy Synthes, West Chester, PA, EUA) were used in three patients.
Tantalum cones were implanted in the tibia in 10 patients, while femoral cones were needed in 2 and a trabecular metal cones were used in 1 patient. ►Table 2 shows the classification of the bone defects. The patient who required tantalum cone in the femur and in the tibia had an AORI 3 defect in the femur and a 2b defect in the tibia (►Figure 4).

| Tibia | Femur | |
|---|---|---|
| 1 | 0 | 0 |
| 2a | 1 | 0 |
| 2b | 6 | 0 |
| 3 | 3 | 2 |
| 10 | 2 |
The analysis of sequential radiographic images showed that all 11 patients showed signs of osteointegration of the implant. We did not observe signs of loss or migration of the trabecular metal cone or of the prosthetic components in any patient as well as no signs of osteolysis.
Two patients had early complications, one of which with a subcutaneous hematoma that required surgical procedures for drainage and control. The second patient presented with erysipelas with erysipelas in the operated limb 20 days after surgery, requiring hospitalization for antibiotic therapy and resolution of the condition. During the study period, we did not observe of complications or reoperations directly related to the use of tantalum cones.
During the follow-up period, two patients required reoperations, totaling four surgeries. One of them, previously mentioned for hematoma drainage in two approaches, was submitted to an extensor mechanism transplantation due to osteonecrosis and fragmentation of the native patella after a 4-year follow-up. The second patient with no tantalum femoral cone had loosening associated with sinking of the femoral component 9 years after the initial surgery, and had to have a revision of the femoral component. During the intraoperative evaluation, the tibial tantalum was fixed and with signs of osteointegration (►Figure 5).
DISCUSSION
The optimal treatment of large bone defects in complex primary or knee revision arthroplasties remains undefined. More recently, tantalum TM cones have demonstrated promising results in short-term evaluation for the treatment of these bone losses. However, the duration of support capacity, and clinical results in the medium- and long-term, require evidence.12-16 Our main result was to demonstrate the absence of mechanical failures and migration of prosthetic components with the use of metaphyseal cones in the medium-term evaluation.
Although short-term clinical results with tantalum cones are favorable,6-9,11,20-23 there are few studies evaluating medium-term results.16-18 Tantalum is a transition metal that remains relatively inert in vivo. It is a structure of open cells in dodecahedrons in sequence, thus simulating the microstructure of the cancellous bone. Therefore, it is quite attractive as a biomaterial due to its low stiffness, high porosity, and high coefficient of friction, besides serving as a structure for osteoblastic activity. In general, bone growth in pores occurs on average 13% in 2 weeks, 53% in 4 weeks, and up to 80% in 1 year, and it is possible to verify evidence of osteointegration on radiographs in an average period of 36 months.27 The low modulus of elasticity, similar to cortical and cancellous bone, reduces bone resorption in the periphery of the implant by inadequate load distribution, favoring the maintenance of bone mineral density around the implant. This is an advantage, considering the frequent need for high constriction in complex primary and revision TKA.28 In our study, semiconstricted implants were used in three patients, and constricted implants in eight patients.
In addition, the high coefficient of friction provides immediate mechanical stability; therefore, the impaction of cones in the metaphyseal bone offers strong instantaneous mechanical support that allows controlling the rotational forces of the implants, protecting fixation and bone ingrowth. Proper stress transfer also allows the use of shorter stems.25,28 Other important characteristics are low cytotoxicity and leukocyte activation capacity, making it one of the most biocompatible materials to date, what may be an interesting feature in infected revision arthroplasties.25,29
In the present study, 3 patients (36.36%) required four reoperations due to complications with the surgical wound, with the extensor mechanism, and loosening of the femoral component. This rate is higher than that found in the meta-analysis performed by Divano et al.,30 who, when analyzing 19 studies, showed an average rate of reoperations of 16.19%. However, the reoperations in our study were not directly related to complications of the metaphyseal cone. Most studies of this meta-analysis showed early results of the use of tantalum cones, with a mean follow-up of 3.65 years. Our rates are closer to those of a study with a longer follow-up such as that presented by Kamath et al.,25 who evaluated, for 70 months, 63 patients who were treated with tibial cones in revisions TKAs and had 24% of reoperations. Similarly, it also approximates the rates observed by Potter et al.,24 who found a survival rate of 70% in 5 years.
In our sample, all patients showed signs of osteointegration on X-ray at the last follow-up follow-up. These results are in line with other studies6-9,11,20-22 that analysed a total of 285 cones in 242 knees submitted to TKA revision and that demonstrated that in only 2 knees (0.7%) there were no radiographic signs of bone ingrowth.
The present study has limitations, many of which inherent to its retrospective nature. We recognize the subjectivity that radiographic analysis presents, particularly when performed retrospectively, and we tried to mitigate this inaccuracy through the opinion of 3 surgeons with 13, 20 and 37 years experience in knee surgery. Another important factor is that the study population is characteristically formed by elderly patients, and it is possible have had some loss to follow-up by decease. In addition, the group of patients is relatively small, but similar to those of previous studies.6-9,11,20,21-23 Thus, in a series with a limited number of patients, it is impossible to detect unusual complications and low-frequency events that may be clinically important. Nevertheless, this is one of the few studies in Brazil that describes the results of the treatment of large bone defects with tantalum metaphyseal cones.
CONCLUSIONS
In our study, tantalum metaphyseal cones showed to be or demonstrated to be able to provide efficient structural support to prosthetic implants with radiographic signals of osteointegration in the medium-term. Therefore, the use of trabecular metal cones represents an attractive option for the treatment of large bone defects in complex primary and revision TKAs. However, prospective studies with a larger sample and longer follow-up is warranted.